Availability: | |
---|---|
XRMD21011103
XINDRAY
Electric Surgical Diathermy Machine
Products feature
The output power: 300W
The six output modes: pure cut the mixed cut 1 mixed cut 2 spray concrete the soft the standard bipolar coagulation
The entire microcomputer control, three output power digital display output with different indications of acousto-optic
It can be matched with laparoscopy, hysteroscopy using, applicable to branches class operation
We have the plate detection system (REM), power compensation system (PPS)
It has a remote control to adjust the output function pen
- no external fan cooling, suitable for laminar flow operation room
The technical parameters:
1. the environmental temperature range: 5 to 40 DEG c;
2. the relative humidity range: less than or equal to 80;
3. the atmospheric pressure range: 86 ~ 106.0kPa;
4. power: 220V + 22V, 50Hz + 1Hz.
5. working frequency: 416KHz
6. the rated output power:
A) pure cut: 1W ~ 300W (load of 800 ohm);
B) 1: 1W ~ 200W mixed cutting (load of 800 ohm);
C) 2: 1W ~ 250W mixed cutting (load of 800 ohm);
D) shotcrete: 1W ~ 80W (load of 800 ohm);
E) soft coagulation: 1W ~ 120W (load of 800 ohm);
F) bipolar coagulation: 1W ~ 50W (load of 200 ohm);
7. the whole power consumption: less than 1100VA.
8. transportation and storage:
a) the ambient temperature range: 40 to 55 DEG c;
b) The relative humidity range: less than or equal to 95%;
C) atmospheric pressure range: 500hPa ~ 1060hPa.
The standard configuration:
Electric knife pen 5, neutral electrode 10, plate wire 1, 1 sets of bipolar forceps and special cable, cleaning tablets 1, switch 1 feet
Electric Surgical Diathermy Machine
Products feature
The output power: 300W
The six output modes: pure cut the mixed cut 1 mixed cut 2 spray concrete the soft the standard bipolar coagulation
The entire microcomputer control, three output power digital display output with different indications of acousto-optic
It can be matched with laparoscopy, hysteroscopy using, applicable to branches class operation
We have the plate detection system (REM), power compensation system (PPS)
It has a remote control to adjust the output function pen
- no external fan cooling, suitable for laminar flow operation room
The technical parameters:
1. the environmental temperature range: 5 to 40 DEG c;
2. the relative humidity range: less than or equal to 80;
3. the atmospheric pressure range: 86 ~ 106.0kPa;
4. power: 220V + 22V, 50Hz + 1Hz.
5. working frequency: 416KHz
6. the rated output power:
A) pure cut: 1W ~ 300W (load of 800 ohm);
B) 1: 1W ~ 200W mixed cutting (load of 800 ohm);
C) 2: 1W ~ 250W mixed cutting (load of 800 ohm);
D) shotcrete: 1W ~ 80W (load of 800 ohm);
E) soft coagulation: 1W ~ 120W (load of 800 ohm);
F) bipolar coagulation: 1W ~ 50W (load of 200 ohm);
7. the whole power consumption: less than 1100VA.
8. transportation and storage:
a) the ambient temperature range: 40 to 55 DEG c;
b) The relative humidity range: less than or equal to 95%;
C) atmospheric pressure range: 500hPa ~ 1060hPa.
The standard configuration:
Electric knife pen 5, neutral electrode 10, plate wire 1, 1 sets of bipolar forceps and special cable, cleaning tablets 1, switch 1 feet