Availability: | |
---|---|
XRME20220301020
XINDRAY
Features:
Accurate test result
Sample probe with function of clot detection
Reagent disk refrigerated at 2-8℃
Unique design of reagent kits, non-contact mixing method
Non-contact multi-position mixing method of reaction disk
Precise magnetic particles separation technology
Quality control and calibrators need no pre-treatment
Humanized functional design
Unique sample rack design
Integrate reagent kits design, flexible test package setting
Intelligent &personalized software design
Test countdown
Standby countdown
Maintenance countdown
Efficient working mode
Time to first result: 11 minutes
Batch test throughput up to 180 T/H
90 sample positions
Flexible STAT priority function
25 reagent positions
Reagents auto registered
Samples and consumables on-board loading
Specifications:
Technology principle | Magnetic chemiluminescence |
Detection Platform | Avidin-Acridinium Ester Chemiluminescence |
Throughput | 180 T/H |
Reagent position | 25 positions |
Reagent storage temperature | 2~8℃ |
Sample position | 90 positions |
Barcode reader | Internal |
Sampling technology | Liquid level detection |
Interface | Network interface |
Connect LIS/HIS system | Able to connect LIS/HIS |
Weight | About 200kg |
Power consumption | About 1000VA |
Dimension | 1230mm*757mm*554mm(L*W*H) |
Power supply | 220±22VAC/110±11VAC |
Features:
Accurate test result
Sample probe with function of clot detection
Reagent disk refrigerated at 2-8℃
Unique design of reagent kits, non-contact mixing method
Non-contact multi-position mixing method of reaction disk
Precise magnetic particles separation technology
Quality control and calibrators need no pre-treatment
Humanized functional design
Unique sample rack design
Integrate reagent kits design, flexible test package setting
Intelligent &personalized software design
Test countdown
Standby countdown
Maintenance countdown
Efficient working mode
Time to first result: 11 minutes
Batch test throughput up to 180 T/H
90 sample positions
Flexible STAT priority function
25 reagent positions
Reagents auto registered
Samples and consumables on-board loading
Specifications:
Technology principle | Magnetic chemiluminescence |
Detection Platform | Avidin-Acridinium Ester Chemiluminescence |
Throughput | 180 T/H |
Reagent position | 25 positions |
Reagent storage temperature | 2~8℃ |
Sample position | 90 positions |
Barcode reader | Internal |
Sampling technology | Liquid level detection |
Interface | Network interface |
Connect LIS/HIS system | Able to connect LIS/HIS |
Weight | About 200kg |
Power consumption | About 1000VA |
Dimension | 1230mm*757mm*554mm(L*W*H) |
Power supply | 220±22VAC/110±11VAC |