XRMD210107010
XINDRAY
Transport Infant Incubator
Product features
Two temperature control modes: Air mode and Baby mode controlled by micro-computer;
Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately;
Failure alarm indication;
Can be equipped with >37℃ temperature set function;
Double wall Acrylic glass hood with side door so that the bassinet can be pulled out from it;
Natural air flow humidity;
The height of whole unit can be adjusted;
Oxygen supply system;
Observation lamp.
Specification:
1.AC power requirement:AC220V-230V/50Hz or AC110-120V/50-60Hz, 400VA
DC Power requirement: DC 12V/10A or DC24V/6A
2.Air temperature control range:25°C-37°C (Override mode 37°C-38°C)
3.Baby temperature control range:34°C-37°C (Override mode37-37.5°C)
Skin temperature sensor accuracy: ±0.2°C
4.The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition): ≦1.0°C
Temperature uniformity: ≦1.5°C (mattress is on the horizontal position)
5.Battery continuous working time:90min (Set temperature is 36°C-Ambient temperature is 15°C)
Standard Configuration:
Main body (Including the Hood, Controller, Bassinet, Internal battery, and Observation Lamp), Oxygen cylinders, Oxygen supply system, Skin temperature sensor, I.V. Pole, Mattress, Adjustable stand).
Optional Configuration:
“>37℃” override temperature mode, Disposable skin temperature sensor, Ambulance trolley.
Environment temperature:
Operating range: 10°C~30°C (Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: >0.3m/s, <1.0m/s
Package:
Main body and Cabinet are packed into two cartons
Dimension (Main body): 1090mm*655mm*760mm, 80kgs;
(Cabinet): 1380mm*610mm*400mm, 53kgs
Transport Infant Incubator
Product features
Two temperature control modes: Air mode and Baby mode controlled by micro-computer;
Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately;
Failure alarm indication;
Can be equipped with >37℃ temperature set function;
Double wall Acrylic glass hood with side door so that the bassinet can be pulled out from it;
Natural air flow humidity;
The height of whole unit can be adjusted;
Oxygen supply system;
Observation lamp.
Specification:
1.AC power requirement:AC220V-230V/50Hz or AC110-120V/50-60Hz, 400VA
DC Power requirement: DC 12V/10A or DC24V/6A
2.Air temperature control range:25°C-37°C (Override mode 37°C-38°C)
3.Baby temperature control range:34°C-37°C (Override mode37-37.5°C)
Skin temperature sensor accuracy: ±0.2°C
4.The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition): ≦1.0°C
Temperature uniformity: ≦1.5°C (mattress is on the horizontal position)
5.Battery continuous working time:90min (Set temperature is 36°C-Ambient temperature is 15°C)
Standard Configuration:
Main body (Including the Hood, Controller, Bassinet, Internal battery, and Observation Lamp), Oxygen cylinders, Oxygen supply system, Skin temperature sensor, I.V. Pole, Mattress, Adjustable stand).
Optional Configuration:
“>37℃” override temperature mode, Disposable skin temperature sensor, Ambulance trolley.
Environment temperature:
Operating range: 10°C~30°C (Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: >0.3m/s, <1.0m/s
Package:
Main body and Cabinet are packed into two cartons
Dimension (Main body): 1090mm*655mm*760mm, 80kgs;
(Cabinet): 1380mm*610mm*400mm, 53kgs