Clinical Application
1. Hemodialysis Therapy
2. Pure ultrafiltration Therapy
3. Hemoperfusion Therapy
4. Plasma exchange Therapy
5. Na+and UF profiling
Availability: | |
---|---|
XRME210210133
XINDRAY
Clinical Application
1. Hemodialysis Therapy
2. Pure ultrafiltration Therapy
3. Hemoperfusion Therapy
4. Plasma exchange Therapy
5. Na+and UF profiling
Kt/V function
1.The sufficiency of dialysis can be reflected by Kt/V.
2.HCO3 adjustment function:
3.Be applicable for sericous acid toxicosis patient.
4.Be capable to calibrate the acid toxicosis status according to patient's state of illness.
5.Backup power-supply:
6.It can last for 15-30 minutes after power cut off.
Technical Specification:
Dimensions and weight | |
Dimensions(mm) | 1460*490*715 |
Weight | 85kg |
Work Condition and Connector | |
Power supply | AC 100~240v, 47~63HZ |
Water Temperature | 5~35℃ |
Water Pressure | 0~8.0bar |
Connector | Ethernet, RS232/RS485, USB |
Blood and Substitution | |
Blood Flow | 0~700ml/min, Accuracy: ±10ml/min |
Substitution Flow | 0~650ml/min, Accuracy: ±10ml/min |
Substitution flow range | 0~39L/h (HDF-Online) |
Dialysate | |
Dialysate Flow | 0, 100ml/min~1000ml/min, ±5% |
Dialysate Temperature | 33℃~40℃, Accuracy: ±0.5℃ |
Dialysate Conductivity | 12.0Ms/cm~18.0mS/cm |
Clean and Disinfection | |
Decalcification | Rinse, Citrate Sodium or Glacial Acetic Acid |
Thermal Disinfection | Hot Water or Citrate Sodium (≥93℃) |
Chemical Disinfection | Sodium Hypochlorite or Peracetic Acid |
Dehydration Control | |
Dehydration Speed | 0~6000ml/h, Accuracy: ±30ml/h |
Dehydration Range | 0~99L |
Heparin Pump | |
Heparin Pump Flow | 0~10ml/h |
Syringe Size | 10ml, 20ml, 30ml, 50ml |
Rapid Injection Rate | 10~1800ml/h |
Clinical Application
1. Hemodialysis Therapy
2. Pure ultrafiltration Therapy
3. Hemoperfusion Therapy
4. Plasma exchange Therapy
5. Na+and UF profiling
Kt/V function
1.The sufficiency of dialysis can be reflected by Kt/V.
2.HCO3 adjustment function:
3.Be applicable for sericous acid toxicosis patient.
4.Be capable to calibrate the acid toxicosis status according to patient's state of illness.
5.Backup power-supply:
6.It can last for 15-30 minutes after power cut off.
Technical Specification:
Dimensions and weight | |
Dimensions(mm) | 1460*490*715 |
Weight | 85kg |
Work Condition and Connector | |
Power supply | AC 100~240v, 47~63HZ |
Water Temperature | 5~35℃ |
Water Pressure | 0~8.0bar |
Connector | Ethernet, RS232/RS485, USB |
Blood and Substitution | |
Blood Flow | 0~700ml/min, Accuracy: ±10ml/min |
Substitution Flow | 0~650ml/min, Accuracy: ±10ml/min |
Substitution flow range | 0~39L/h (HDF-Online) |
Dialysate | |
Dialysate Flow | 0, 100ml/min~1000ml/min, ±5% |
Dialysate Temperature | 33℃~40℃, Accuracy: ±0.5℃ |
Dialysate Conductivity | 12.0Ms/cm~18.0mS/cm |
Clean and Disinfection | |
Decalcification | Rinse, Citrate Sodium or Glacial Acetic Acid |
Thermal Disinfection | Hot Water or Citrate Sodium (≥93℃) |
Chemical Disinfection | Sodium Hypochlorite or Peracetic Acid |
Dehydration Control | |
Dehydration Speed | 0~6000ml/h, Accuracy: ±30ml/h |
Dehydration Range | 0~99L |
Heparin Pump | |
Heparin Pump Flow | 0~10ml/h |
Syringe Size | 10ml, 20ml, 30ml, 50ml |
Rapid Injection Rate | 10~1800ml/h |