1.Automatic probe cleaning, liquid level detection, collision protection
2.24 hour non-stop working,convenient emergency function with inserting emergency samples at random.
3.Discrete cuvette, preventing from crossinfection, and be washed and reused, making sure accurate result and save cost.
4.Perfect function of quality control management, convenient to manage the clinical test result.
5.Detecting in the whole reaction process with reaction curve, convenient for users to
monitor thoroughly and scientifically analyze the detection data.
Availability: | |
---|---|
XRME210305115
XINDRAY
Feature:
1.Self-checking function.
2.Filter choosing-mode: automatically.
3.Large memory to pre-store 126 programs and save detection res Its on 105 pieces of plates.
4.Internal printer and external printer via so ware.
5.Checking mode: single wave/dual wave detection.
6.High sensitivity high accuracy, fast detection speed and friendly operation.
Technical Specification:
Range of working | 400nm-800nm |
Measurement System: | 8 Channel optical system |
Filters | 4 standard filters (405, 450, 492, 630nm), or totally 10 filters can be installed |
Reading Speed | Single wave: 5s, dual waves: 10s |
Measurement Range | 0.000~4.000Abs |
Photometric Accuracy | ±0.01Abs (0.001~1.500Abs) |
Stability | <0.005Abs |
Linearity | <±1% (0.001~1.500Abs) |
Display | 5” TFT LCD |
System | Win 7 and Win XP, LIS, HIS |
Calculation Method | Two-point, Linear regression method, Semi logarithmic method, Ratio log method, Full log method, Exponential regression (LOGA-C), Logit-Log, Point to point (Broken line method), Four parameter method, Two square curve, Three square curve and Three square spline |
Printer | Built-in thermal print |
Data Communication | RS232 |
Power Supply | AC220V/110V±10%, 50HZ/60HZ |
Dimension | 420*350*181(mm) |
Weight | 9kg |
Feature:
1.Self-checking function.
2.Filter choosing-mode: automatically.
3.Large memory to pre-store 126 programs and save detection res Its on 105 pieces of plates.
4.Internal printer and external printer via so ware.
5.Checking mode: single wave/dual wave detection.
6.High sensitivity high accuracy, fast detection speed and friendly operation.
Technical Specification:
Range of working | 400nm-800nm |
Measurement System: | 8 Channel optical system |
Filters | 4 standard filters (405, 450, 492, 630nm), or totally 10 filters can be installed |
Reading Speed | Single wave: 5s, dual waves: 10s |
Measurement Range | 0.000~4.000Abs |
Photometric Accuracy | ±0.01Abs (0.001~1.500Abs) |
Stability | <0.005Abs |
Linearity | <±1% (0.001~1.500Abs) |
Display | 5” TFT LCD |
System | Win 7 and Win XP, LIS, HIS |
Calculation Method | Two-point, Linear regression method, Semi logarithmic method, Ratio log method, Full log method, Exponential regression (LOGA-C), Logit-Log, Point to point (Broken line method), Four parameter method, Two square curve, Three square curve and Three square spline |
Printer | Built-in thermal print |
Data Communication | RS232 |
Power Supply | AC220V/110V±10%, 50HZ/60HZ |
Dimension | 420*350*181(mm) |
Weight | 9kg |